Lvl nelsonpine co nz www nelsonpine co nz nelsonpine lvl11 floor joists 100x45 floor joists supporting floor loads only 40kg m2 joint spacing 300 450 600 span o h span o h span o h dxb maximum single span 100x45 2300 550 1850 500 1750 400 maximum.
Timber floor joist span tables nz.
These span tables have been developed in good faith with the assistance of mr peter falvey b e m i e aust c p eng r p e q 579 in accordance with the relevant australian standards however please check for state and local government variations.
Loading data is taken from as nzs1170 2002 structural design actions to satisfy the requirements of section b1 of the new zealand building code.
Listed are 46 tables based on common loading conditions for floor joists ceiling joists and rafters.
64 3 543 8800 f.
Characteristic properties are determined in accordance with as nzs 4063 2 2010 and so comply with the provisions of the new zealand building code through clause 2 3 for engineering design in accordance with nzs3603 1993 timber structures standard.
All technical information and span tables in this guide are in accordance with the product specific design properties.
Use the span tables below to determine allowable lengths of joists and rafters based on size and standard design loads.
Timber subfloor framing timber was typically boric treated pinus radiata although heart rimu was used in some areas for bearers.
View allowable load tables.
Lib88s floor joist span tables the lumberworx i beam is perfect for use as a floor joist due to its ability to have service penetrations and strength.
These span tables are only for use in conjunction with taranakipinetm timber products.
New zealand po box 3049 richmond nelson 7050 t.
The introduction of nzs 3604 in 1978 saw the requirements for bearer and joist size span and spacing clearly specified.
View size selection tables.
64 3 543 8890 e.
Consisting of structural lvl flanges with a structural plywood web hyjoist is lightweight and easy to install.
Lib88s rafters span tables the lumberworx i beam is light which aides in installation.
Residential span tables available refer brochures below.
Subject to design considerations.
Apa performance rated i joists pris are manufactured in accordance with pri 400 performance standard for apa ews i joists form x720 this performance standard provides an easy to use table of allowable spans for applications in residential floor construction allowing designers and builders to select and use i joists from various member manufacturers using just one set of span.
View joist rafter tables.
As1720 1 2010 timber structures design methods.